OiD20Ah-50.4 50.4V 20Ah Lithium Ion Battery Pack 50A 300Cycle
Product Name
Lithium-Ion Battery Pack (Li-ion)
Advantages
Specifications
Parameter |
Value |
Unit |
Comments |
Nominal Voltage |
50.4V |
DC |
Non-parallel/series connection allowed. |
Rated Capacity |
20Ah |
@0.5C |
Based on 14S4P cell configuration (IFR32700-5A 3C). |
Max Charge Current |
10A (25°C±2) |
@Constant Current (CC) |
Up to 58.8V (constant voltage phase). |
Max Discharge Current |
50A (0°C–45°C) |
@Constant Current (CC) |
Min discharge voltage: 2.7V/cell. |
Terminal Configuration |
Red UL3135-12AWG (+), Black UL3135-12AWG (-) |
Connector Type |
For high-current applications. |
AC Impedance |
≤160mΩ |
@1kHz |
Measured with digital impedance analyzer. |
Weight |
~4.5kg |
Including enclosure and connectors. |
|
Dimensions |
195mm(L) × 185mm(W) × 80mm(H) |
Excluding wiring harness. |
Cycle Life
Test Conditions |
Cycle Count |
Capacity Retention |
Standard |
0.5C Charge + 0.5C Discharge |
300 cycles |
≥97% @100%DOD |
IEC 61434-2015 (equivalent) |
Typical Discharge Profile:
Operating Temperature Range
Category |
Range |
Unit |
Standard Compliance |
Charge Temperature |
0°C – 45°C |
℃ |
GB/T 36276-2018 |
Discharge Temperature |
-20°C – 60°C |
℃ |
GB/T 36276-2018 |
Storage Temperature |
-20°C – 45°C |
℃ |
≤1 month (50% SOC); ≤12 months (25°C SOC) |
Certifications
Key Features
BMS Specifications
Function |
Setting |
Threshold |
Action |
Cell Overvoltage |
Enable |
4.25V ±0.03 |
Cut-off + recovery after <3 seconds. |
Cell Undervoltage |
Enable |
2.7V ±0.1 |
Cut-off + recovery after <1.5 seconds. |
Battery Overvoltage |
Enable |
58.8V |
Cut-off + recovery after <1.05 seconds. |
Battery Undervoltage |
Enable |
2.7V |
Cut-off + recovery after <5 seconds. |
Temperature Protection |
Charge: 52°C / Discharge: 65°C |
±5°C Sampling Error |
Cut-off + recovery when temp returns to threshold. |
Applications
Usage Warnings & Precautions
Storage Guidelines
Warranty & Disclaimer