OiD2Ah-22.2 22.2V 2Ah Lithium Ion Battery Pack 5A 300Cycle
Product Name
Lithium-Ion Battery Pack (Li-ion)
Advantages
Specifications
Parameter |
Value |
Unit |
Comments |
Model |
OiD2Ah-22.2 |
- |
6S1P Li-ion battery pack |
Nominal Voltage |
22.2V |
DC |
6S series connection (3.7V/cell). |
Rated Capacity |
2Ah |
@0.5C |
Based on 20±5℃ testing. |
Standard Charge Current |
0.5A |
@CC/CV |
Charges to 25.5V±0.15V (adapter output: 27V/0.5A). |
Standard Discharge Current |
5A |
@CC |
Discharges to 16.5V±0.15V (20±5℃). |
Max Charge Current |
0.5A (0–45℃) |
@CC |
Up to 25.5V (constant voltage phase). |
Max Discharge Current |
5A (-20–60℃) |
@CC |
Min discharge voltage: 16.5V/cell. |
Terminal Configuration |
Red UL3239AWG14 (+), Black UL3239AWG14 (-) |
Connector Type |
High-current terminals for robust connections. |
Internal Resistance |
≤250mΩ |
@1kHz |
Ensures efficient energy delivery. |
Weight |
Approximately 430g |
Including enclosure and wiring. |
|
Dimensions |
TBD (Based on two-row internal layout) |
Optimized for space efficiency. |
Cycle Life
Test Conditions |
Cycle Count |
Capacity Retention |
Standard |
20±5℃, 0.5C charge + 5A discharge |
300 cycles |
≥60% initial capacity |
IEC 61434 (equivalent) |
Typical Discharge Profile:
Operating Temperature Range
Category |
Operating Range |
Unit |
Standard Compliance |
Charge Temperature |
0°C – 45°C |
℃ |
GB/T 31486-2015 |
Discharge Temperature |
-20°C – 60°C |
℃ |
GB/T 31486-2015 |
Storage Temperature |
-20°C – 45°C |
℃ |
≤12 months (30% SOC) |
Certifications
Key Features
BMS Specifications
Function |
Threshold |
Delay Time |
Action |
Overcharge Detection |
4.25V ±0.025V |
2 seconds |
Cut-off + auto-recovery. |
Overdischarge Detection |
2.75V ±0.025V |
2 seconds |
Cut-off + auto-recovery. |
Overcurrent Protection |
15A ±2A |
0.8 seconds |
Fusing + load removal. |
Temperature Protection |
Charge: 51±2℃ |
5 seconds |
Cut-off + auto-recovery when temp returns. |
Applications
Usage Warnings & Precautions
Storage Guidelines
Warranty & Disclaimer